Vertex M™ is an economical way to install, augment or upgrade a gas monitoring system for industries using toxic . It provides a flexible 8 to 24 points of monitoring for use with up to 3 Chemcassette analyzers or combination 1 pyrolyzer analyzer/1 universal Chemcassette analyzer; comes in a small, space-saving cabinet; 110V or 220V power options; and uses the industry’s most reliable toxic gas monitoring technology, colorimetric Chemcassette, which shows proof of a gas response through a telltale stain on the Chemcassette tape. The Vertex M integrates easily into a factory automation system or HMI to serve semiconductor, PV, nano, specialty chemical, lab and other High Tech/Industrial environments.

 

Additional Features and Benefits:

Cost Effective

  • Extended tapes (90 days) provides longer monitoring life
  • No calibration or flow balancing required
  • Additional pump and internal power module increase uptime
  • Software can be configured with out taking unit offline
  • Sampling points can be up to 400 feet (121m) from the monitor and routed to more than one analyzer. 

 

  • Easy to use
  • Touch screen for easy access to data
  • Software updates via CD-ROM or network to all system components
  • Configuration profile editing and data retrieval are all achievable without taking unit offline
  • Radio frequency identification tag (RFID) ensures Chemcassettes® are installed into appropriately programmed analyzer, eliminating human error
  • On-line help system

 

Security

  • Multiple levels of password protection
  • Reconfigure security setup without taking unit offline

 

Low cost of ownership

  • Small footprint and greater density of points reduce your cost per point
  • Eight points per analyzer lowers Chemcassette® costs
  • Maximized 24 point systems provide low cost per point as compared to other continuous monitors
  • One system monitors up to three gas families and more than 40 gases
  • You can split your sample to more than one analyzer

 

Easy to maintain

  • Uses cost-effective XP Chemcassettes®, providing up to three months of continuous monitoring
  • Simplified replacement of Chemcassettes® and automated optics verification
  • No dynamic calibration required
  • No flow balancing
  • Easy access to analyzers, pumps, power supplies and touch screen from front panel
  • Onscreen interactive electronic manual

 

Advanced communications

  • Built-in configurable PLCs with optional 64 relay contacts
  • Standard OPC interface for easy integration into your existing factory automation system or HMI
  • Optional Ethernet/CIP, LONWORKS®, DeviceNetTM, DF1Interface, PROFIBUS, Modbus Plus, Modbus/TCP or ControlNet outputs available
  • Product Info

    Provides a flexible 8 to 24 points of monitoring using colorimetric Chemcasstte®, the industry’s most reliable gas monitoring technology.

     

    Features & Benefits

    • Longer monitoring life with extended tapes (90 days)
    • Touch screen for easy data access
    • No dynamic calibration required

     

    Quick Specs

    • Power requirements: 110 or 230 VAC
    • Operating temperature: 59° to 95°F (15° to 35°C)
    • Operating humidity: 20-65% RH
  • Downloads

  • Cassette Types

    SP Chemcassettes® For TLD-1, SPM, Series 7100 and System 16 Monitoring Systems 

    • 706002 Ammonia
    • 706042 Aliphatic Amines/Ammonia
    • 711314 Bromine
    • 704006 Chlorine/Chlorine Dioxide (1)
    • 704007 Chlorine/Oxidizers (1)
    • 700506 Diisocyanates
    • 1750-9306 Fluorine
    • 708013 Hydrazines
    • 705502 Hydrides
    • 702505 Hydrogen Chloride-for Series 7100 (ppm level)
    • 704510 Hydrogen Cyanide-for TLD-1 and SPM Monitors
    • 700278 Hydrogen Peroxide
    • 701012 Hydrogen Sulphide
    • 705505 Mineral Acids
    • 703012 Nitrogen Dioxide
    • 704514 Ozone
    • 702020 Phosgene
    • 709528 Aromatic Amines/PPD
    • 705015 Sulphur Dioxide
    • 705027 Sulphur Dioxide, Low Level

     

    EP Chemcassettes® - For Model SPM Monitors Only 

    • 700342 Aliphatic Amines/Ammonia
    • 700343 Aromatic Amines/PPD
    • 700313 Bromine
    • 700302 Chlorine/Chlorine Dioxide
    • 700309 Diisocyanates
    • 1740-9306 Fluorine
    • 700347 Hydrazines 
    • 700300 Hydrides
    • 700509 Hydrogen Peroxide
    • 700304 Hydrogen Sulphide 
    • 700337 Mineral Acids
    • 700305 Nitrogen Dioxide
    • 700307 Phosgene 
    • 700350 Sulphur Dioxide, Low Level

     

    LP Chemcassettes® - For Series 7100 and System 16 only

    • 711342 Aliphatic Amines/Ammonia 
    • 711302 Chlorine/Chlorine Dioxide 
    • 711309 Diisocyanates 
    • 1830-9306 Fluorine
    • 711300 Hydrides
    • 711304 Hydrogen Sulphide
    • 711337 Mineral Acids (1)
    • 711305 Nitrogen Dioxide (2) 
    • 711307 Phosgene 


    CM4 Chemcassette® - For the Model CM4 Toxic Gas Monitor 

    • 874342 Aliphatic Amines/Ammonia
    • 874007 Chlorine (monitors up to 16 days) 
    • 1874-9306 Fluorine
    • 874347 Hydrazine 
    • 874300 Hydrides 
    • 874510 Hydrogen Cyanide (monitors up to 16 days)
    • 874304 Hydrogen Sulphide 
    • 874337 Mineral Acids 
    • 874307 Phosgene 
    • 874568 Sulphur Dioxide

     

    EGM Chemcassettes® - For the Model EGM only 

    • 856342 Aliphatic Amines/Ammonia 
    • 856302 Chlorine/Chlorine Dioxide 
    • 856300 Hydrides 
    • 856337 Mineral Acids
    • 856307 Phosgene

     

    Vertex Chemcassettes® - For Vertex only 

    • 1295-0221 Aliphatic Amines/Ammonia
    • 1295-0220 Fluorine (for F2, NO2) 
    • 1295-0300 Hydrides 
    • 1295-0222 Hydrogen Cyanide (monitors up to 2 weeks) 
    • 1295-0225 Mineral Acids
    • 1295-0552 Sulphur Dioxide 

     

    Extended Play XP Chemcassettes® -for 1 to 3 months Service Life 

    • 1295-0227 XPV for Chlorine (Vertex) 
    • 1830-9308 XPL for Chlorine (System 16)
    • 1874-9308 XPC for Chlorine (CM4) 
    • 1740-9308 XPS for Chlorine (SPM)
    • 1756-9308 XPE for Chlorine (EGM) 
    • 1750-9308 XPT for Chlorine (TLD) 
    • 1295-0226 XPV for Hydrides (Vertex) 
    • 1830-9300 XPL for Hydrides (System 16) 
    • 1874-9300 XPC for Hydrides (CM4) 
    • 1740-9300 XPS for Hydrides (SPM) 
    • 1756-9300 XPE for Hydrides (EGM*) 
    • 1750-9300 XPT for Hydrides (ChemKey-TLD**) 
    • 1295-0228 XPV for Phosgene (Vertex) 
    • 1874-9307 XPC for Phosgene (CM4) 
    • 1740-9307 XPS for Phosgene (SPM)
    • 1756-9307 XPE for Phosgene (EGM) 
    • 1295-0405 XPV for Ammonia (Vertex) 
    • 1830-9309 XPL for Ammonia (System 16)
    • 1874-9309 XPC for Ammonia (CM4)
    • 1740-9309 XPS for Ammonia (SPM) 
    • 1756-9309 XPE for Ammonia (EGM)
    • 1295-0507 XPV for Mineral Acids (Vertex)
    • 1874-9310 XPC for Mineral Acids (CM4) 
    • 1740-9310 XPS for Mineral Acids (SPM) 
    • 1750-9310 XPT for Mineral Acids (TLD) 

     

    Extended Play XP4 Chemcassettes® -for 4 Months Service Life 

    • 1257-9308 XP4-V for Chlorine (Vertex) 
    • 1258-9308 XP4-C for Chlorine (CM4)
    • 1257-9300 XP4-V for Hydrides (Vertex)
    • 1258-9300 XP4-C for Hydrides (CM4) 
    • 1257-9307 XP4-V for Phosgene (Vertex) 
    • 1258-9307 XP4-C for Phosgene (CM4)
    • 1257-9309 XP4-V for Ammonia (Vertex)
    • 1258-9309 XP4-C for Ammonia (CM4) 
    • 1257-9310 XP4-V for Mineral Acids (Vertex)
    • 1258-9310 XP4-C for Mineral Acids (CM4)
  • Delivery

    We aim to Delivery products with you within 4 weeks of receipt of order. However, in exceptional circumstances delivery may be up to 6 weeks due to manufacturer lead times. Please inform us if you require fast delivery as we will do our utmost to expedite your order.

  • Quantity Orders

    Please contact us directly to discuss quantity purchases and additional discounts.  We will subsequently provide you with a formal quote with the applied discount, which will be valid for 30 days 

  • Hire

    Many of the products you have seen are available for hire, so feel free to contact us if you would prefer to hire this instrument.

bottom of page